Chemia Analityczna Volume 46, Number 6
(November - December 2001)

A Simple and Fast Method for the Determination of Ranitidine in Human Plasma by HPLC-DAD

by Victor David1, Mihaela Ionescu2, Florentin Tache1 and Andrei Medvedovici1

1University of Bucharest, Faculty of Chemistry, Department of Analytical Chemistry, Sos. Panduri, no.90, Sect. 5, Bucharest, Romania
2Biopharmacy and Pharmacology Res., Bucharest, Romania


Key words: ranitidine, human plasma, liquid chromatography

A simple and fast method for the determination of ranitidine in plasma samples is described.Thie method is based on plasma  deproteinization in the presence of trichloroacetic acid, and determination by HPLC-DAD, on a XDB C18 column, at 320 nm. Elution was isocratic, using a mobile phase containing 60% phosphate buffer 20 mmol l-1 (pH 7.3) and 40% methanol, with flow rate of 1 ml min-1, at 40 oC. Applied to a bioequivalence study, this method reaches a limit of determination of 15 ng ml-1 ranitidine in plasma samles, for an injection volume of 50 ml.



backback to table of contents